Products

Light oil or gas steel boilers "GS A", 58 to 1160 kW

Light oil or gas steel boilers "GS A", complete with control panel,

 
The „GS А” boilers are constructed with materials of strict quality and durability specifications and in accordance with the Europian standards EN 303-1 и EN 303-3.
 
With high efficiency, big heat surfaces, excelent insulationq easy maintance and long operational life.
 
The boiler body and boiler door insulation, with glass wool and aluminium foil covering, minimize the heat loss and increase the efficiency.
 
TECHNICAL DATA AND DIMENSIONS:

 

Type
Power
kW
Inlet/ outlet water
Dimensions-cm:
W х D х H
 Flue Ø mm
Weight
kg
Hight from the floor to the flue axis cm
Burner type
ECOFLAM
1
GS A 50
58
1 1/2”
61х100х61
Ø150
160
46
MAX 4

2

GS A 60
70
1 1/2”
72х95х84
Ø150
200
66
MAX 8

3

GS A 75
87
2”
72х98х84
Ø180
210
66
MAX 8
4
GS A 90
105
2”
72х111х84
Ø180
224
66
MAX 12
5
GS A 100
116
2”
72х121х84
Ø180
238
66
MAX 12
6
GS A 125
145
2”
76х134х95
Ø200
336
75
MAX 15
7
GS A 150
175
2 1/2”
86х134х111
Ø250
422
88
MAX 20
8
GS A 175
204
2 1/2”
86х142х111
Ø250
455
88
MAX Р 25 АВHS
9
GS A 200
233
3”
86х156х111
Ø250
488
88
MAX Р 25 АВHS
10
GS A 250
290
3”
98х160х111
Ø250
600
78
MAX Р 35 АВ
11
GS A 300
350
3”
98х191х111
Ø300
644
78
MAX Р 35 АВ
12
GS A 350
405
4”
98х206х111
Ø300
708
78
MAX Р 45 АВ
13
GS A 400
465
4”
126х190х136
Ø300
1010
86
MAX Р 45 АВ

14

GS A 450
520
4”
126х200х136
Ø350
1144
86
MAIOR P 60 AB
15
GS A 500
580
4”
126х206х136
Ø350
1290
86
MAIOR P 60 AB
16
GS A 600
700
4”
126х226х136
Ø350
1348
86
MAIOR P 80 AB
17
GS A 700
815
4”
131х232х151
Ø350
1570
96
MAIOR P 80 AB
18
GS A 800
930
4”
131х251х151
Ø400
1626
96
MAIOR P 120 AB
19
GS A 900
1045
4”
131х276х151
Ø400
1950
96
MAIOR P 120 AB
20
GS A 1000
1160
4”
131х301х151
Ø400
2038
96
MAIOR P 120 AB
21  DG 1200  1390  6"  148x272x174  Ø400  2710    MAIOR P 150 AB
22  DG 1400  1620  6"  148x261x174  Ø400  3227    MAIOR P 200 AB

 

 

Related products

Light oil steel boilers STH 23 to 40 kW

The STH boilers, complete with a diesel burner, circulation pump, expansion vessel, safety valve and control panel.

 

Due to their compact size, they are suitable for installation in small spaces.

 

The boilers are factory tested hydrostatically at pressure of 6bar. All the equipment is connected and tested (burner, circulation pump, thermostats).

 

The materials and thickness of the steel plates, used in the construction, comply with EN 303-1 and EN 303-3. 

View more

The Company| Sale |Privacy policy | |Projects |Contacts